Nano-Glo® Live Cell Assay System
Measures NanoLuc® Luminescence in Living Cells
- Substrate and buffer optimized to enhance stability
- Use to detect NanoBiT® protein complementation or NanoLuc® reporter activity
- Monitors luminescence at a single time point or continuously for up to 2 hours without compromising cell viability.
Catalog Number:
Size
Catalog Number: N2011
Catalog Number: N2012
Catalog Number: N2013
Single-Addition Reagent to Detect NanoLuc® Luminescence in Live Cells
The Nano-Glo® Live Cell Assay System is a single-addition, non-lytic detection reagent used to measure NanoBiT® or NanoLuc® luminescence from living cells. The reagent is prepared by diluting the Nano-Glo® Live Cell Substrate with the Nano-Glo® LCS Dilution Buffer to make the Nano-Glo® Live Cell Reagent, a 5X stock that is added directly to cell culture medium. Both substrate and buffer solutions are optimized to provide enhanced stability. The Nano-Glo® Live Cell Reagent is designed to reduce autoluminescence in the presence or absence of serum, increasing the sensitivity for detection of low levels of NanoBiT® or NanoLuc® luminescence. The Nano-Glo® Live Cell Assay System can be used to monitor luminescence at a user-defined time point or continuously for up to 2 hours without compromising cell viability.
Cat.# N2011 is sufficient for 100 assays in 96-well plates; Cat.# N2012 is sufficient for 1,000 assays in 96-well plates, Cat.# N2013 is sufficient for 10,000 assays in 96-well plates.
The signal stability observed after addition of the Nano-Glo® Live Cell Reagent to culture media can be influenced by experimental parameters such as high levels of enzyme activity, temperature or the presence of FBS in the media. Please refer to the Technical Manual for additional information.
Protocols
Specifications
Catalog Number:
What's in the box?
| Item | Part # | Size |
|---|---|---|
Nano-Glo® Live Cell Substrate |
N205A | 1 × 125μl |
Nano-Glo® LCS Dilution Buffer |
N206A | 1 × 2.5ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
See Protocol for detailed storage recommendations.
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no commercial use is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research. Researcher shall have no right to modify or otherwise create variations of the product. No other use or transfer of this product is authorized without the prior express written consent of Promega.
For uses of Nano-Glo®-branded reagents intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than a genetically encoded autofluorescent protein, researchers must:
(i) use NanoBRET®-branded energy acceptors (e.g., BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this product; or
(ii) contact Promega to obtain a license for use of the product for energy transfer assays to energy acceptors not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. No. 9,676,997, European Pat. No. 3146066, Japanese Pat. No. 6641297 and other patents and patents pending.
What's in the box?
| Item | Part # | Size |
|---|---|---|
Nano-Glo® Live Cell Substrate |
N205B | 1 × 1.25ml |
Nano-Glo® LCS Dilution Buffer |
N206B | 1 × 25ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
See Protocol for detailed storage recommendations.
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no commercial use is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research. Researcher shall have no right to modify or otherwise create variations of the product. No other use or transfer of this product is authorized without the prior express written consent of Promega.
For uses of Nano-Glo®-branded reagents intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than a genetically encoded autofluorescent protein, researchers must:
(i) use NanoBRET®-branded energy acceptors (e.g., BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this product; or
(ii) contact Promega to obtain a license for use of the product for energy transfer assays to energy acceptors not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. No. 9,676,997, European Pat. No. 3146066, Japanese Pat. No. 6641297 and other patents and patents pending.
What's in the box?
| Item | Part # | Size |
|---|---|---|
Nano-Glo® Live Cell Substrate |
N205B | 10 × 1.25ml |
Nano-Glo® LCS Dilution Buffer |
N206C | 5 × 50ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
See Protocol for detailed storage recommendations.
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no commercial use is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research. Researcher shall have no right to modify or otherwise create variations of the product. No other use or transfer of this product is authorized without the prior express written consent of Promega.
For uses of Nano-Glo®-branded reagents intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than a genetically encoded autofluorescent protein, researchers must:
(i) use NanoBRET®-branded energy acceptors (e.g., BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this product; or
(ii) contact Promega to obtain a license for use of the product for energy transfer assays to energy acceptors not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. No. 9,676,997, European Pat. No. 3146066, Japanese Pat. No. 6641297 and other patents and patents pending.
Resources
Articles
- Pharmacodynamics of Akt drugs revealed by a kinase-modulated bioluminescent indicator.
- An interaction between SLC35A1 and ST3Gal4 is differentially affected by CDG-causing mutations in the SLC35A1 gene
- Novel NanoLuc substrates enable bright two-population bioluminescence imaging in animals
- In vitro structure–activity relationships and forensic case series of emerging 2‑benzylbenzimidazole ‘nitazene’ opioids
Related Products
Similar Products
Nano-Glo® Extended Live Cell Substrates
Detect NanoLuc® or NanoBiT® reporter activity in live cells for hours or days.
N2570, N2571, N2572, N2580, N2581, N2582, N2590
NanoBiT® PPI Starter Systems
Complementation reporter for detection of protein interactions in live cells.
N2014, N2015, N2016
pNLF1 NanoLuc® Protein Fusion Vectors
Three MCS-based protein fusion vectors that express N- or C-terminal fusions with NanoLuc® luciferase or an N-terminal secreted NanoLuc® reporter.
N1351, N1361, N1371
Nano-Glo® Luciferase Assay System
Add-mix-measure assay for NanoLuc® Luciferase with >2 hour half-life in most applications.
N1110, N1120, N1130, N1150
Frequently Used With
NanoBiT® BiBiT PPI Starter System
Live-cell complementation reporter for PPI assays with single-vector robustness.
CS1603B393, CS1603B394, CS1603B440
FuGENE® HD Transfection Reagent
Enhanced performance in a range of cell types, including difficult-to-transfect cell lines.
E2311, E2312
ViaFect™ Transfection Reagent
High-efficiency, low-toxicity transfection of many cell types, including iPS cells.
E4981, E4982
GloMax® Discover System
High-performance microplate reader for detecting luminescence, fluorescence and absorbance.
GM3000