CytoTox-ONE™ Homogeneous Membrane Integrity Assay
The CytoTox-ONE™ Homogeneous Membrane Integrity Assay is a fluorometric method for estimating the number of nonviable cells present in multiwell plates. The assay rapidly measures the release of lactate dehydrogenase (LDH) from cells with a damaged membrane. LDH released into the culture medium is measured with a 10-minute coupled enzymatic assay that results in the conversion of resazurin into a fluorescent resorufin product. The amount of fluorescence produced is proportional to the number of lysed cells using a 96- or 384-well format. The CytoTox-ONE™ Reagent does not damage normal healthy cells; therefore the reactions set up to measure released LDH can be performed directly in a homogeneous format in assay wells containing a mixed population of viable and damaged cells.
The CytoTox-ONE™ Homogeneous Membrane Integrity Assay, HTP (Cat.# G7892), offers convenient, alternative packaging for processing multiple plates. Each bottle of reagent supplied with the system is sufficient to perform 500 assays in a 96-well format or 2,000 assays in a 384-well format when the recommended volumes are used.
Save time by setting up the assay in a cell culture plate; this eliminates the sample transfer step common in many LDH assays. Plates are then incubated for just 10 minutes before reading data, compared to 30 minutes or more with classic LDH assays.
Multiplexing capability allows you to perform multiple assays on one sample with other homogeneous cell-based assays from Promega.
Adapt the assay protocol to your needs; completed assays can be read over several hours after the provided stop solution has been added while still maintaining good signal.
Protocols
Specifications
Catalog Number:
What's in the box
| Item | Part # | Choose a size |
|---|---|---|
|
Substrate Mix |
G179A | 2 × 1 vial |
|
Lysis Solution |
G182B | 1 × 0.5ml |
|
Assay Buffer |
G790A | 1 × 24ml |
|
Stop Solution |
G791A | 1 × 11ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
What's in the box
| Item | Part # | Choose a size |
|---|---|---|
|
Substrate Mix |
G179A | 10 × 1 vial |
|
Lysis Solution |
G182B | 1 × 0.5ml |
|
Assay Buffer |
G790B | 1 × 120ml |
|
Stop Solution |
G791B | 1 × 60ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
What's in the box
| Item | Part # | Choose a size |
|---|---|---|
|
Substrate Mix |
G179B | 2 × 1 vial |
|
Lysis Solution |
G182B | 1 × 0.5ml |
|
Assay Buffer |
G790B | 1 × 120ml |
|
Stop Solution |
G791B | 1 × 60ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
Resources
No related resources available
Related Products
Similar Products
LDH-Glo™ Cytotoxicity Assay
Bioluminescence-based LDH assay for sensitive detection of cytotoxicity in samples low in cell number, including 3D microtissues.
J2380, J2381
CytoTox-Glo™ Cytotoxicity Assay
Highly sensitive luminescent cytotoxicity assay that measures the relative number of dead cells.
G9290, G9291, G9292
CytoTox-Fluor™ Cytotoxicity Assay
A single-reagent-addition, homogeneous, fluorescent assay that measures the relative number of dead cells in cell populations.
G9260, G9261, G9262
CellTox™ Green Cytotoxicity Assay
Measures changes in membrane integrity. Kinetically monitors cytotoxicity up to 72 hours with multiplex capability.
G8741, G8742, G8743, G8731
Frequently Used With
Caspase-Glo® 9 Assay Systems
Measure caspase-9 activity with this homogeneous, luminescent assay.
G8210, G8211, G8212
Caspase-Glo® 8 Assay Systems
Measure caspase-8 activity with this homogeneous, luminescent assay.
G8200, G8201, G8202
CellTiter-Blue® Cell Viability Assay
Monitor cell viability with this homogeneous, resazurin, fluorescent assay.
G8080, G8081, G8082
CellTiter-Glo® Luminescent Cell Viability Assay
Determine the number of viable cells in culture based on quantitation of ATP present.
G7570, G7571, G7572, G7573